118 HH492 User Guide
Inspect Cords and Connectors
Inspect the interface cable and connector for wear or other signs of damage. A 
badly worn cable or damaged connector may interfere with scanner operation. 
Contact your distributor for information about cable replacement. Cable 
replacement instructions are on page 118.
Replace Cable
The standard interface cable is attached to the scanner with a 10-pin modular 
connector. When properly seated, the connector is held in the scanner’s handle by 
a flexible retention tab. The interface cable is designed to be field replaceable.
• Order replacement cables from Honeywell or from an authorized distributor.
• When ordering a replacement cable, specify the cable part number of the 
original interface cable.
Replace an Interface Cable
1. Turn off the power to the host system.
2. Disconnect the scanner’s cable from the 
terminal or computer.
3. Locate the small hole on the back of the 
scanner’s handle. This is the cable release.
4. Straighten one end of a paper clip.
5. Insert the end of the paper clip into the small 
hole and press in. This depresses the retention 
tab, releasing the connector. Pull the connector 
out while maintaining pressure on the paper 
clip, then remove the paper clip.
6. Replace with the new cable. 
Insert the connector into the opening and press 
firmly. The connector is keyed to go in only one 
way and will click into place.
Replace an Interface Cable in a Base
1. Turn the power to the host system OFF.
2. Disconnect the base’s cable from the terminal or computer.
3. Turn the base upside down.