22 HH492 User Guide
CodeGate™
When CodeGate is On, the trigger is used to allow decoded data to be transmitted
to the host system. The scanner remains on, scanning and decoding barcodes, but
the barcode data is not transmitted until the trigger is pressed. When CodeGate is
Off, barcode data is transmitted when it is decoded. Default = CodeGate Off Out-of-
Stand.
Hands Free Time-Out
The Scan Stand and Presentation Modes are referred to as “hands free” modes. If
the scanner’s trigger is pulled when using a hands free mode, the scanner changes
to manual trigger mode. You can set the time the scanner should remain in manual
trigger mode by setting the Hands Free Time-Out. Once the time-out value is
reached, (if there have been no further trigger pulls) the scanner reverts to the
original hands free mode.
Scan the Hands Free Time-Out barcode, then scan the time-out duration (from 0-
300,000 milliseconds) from the Programming Chart, beginning on page 133, then
Save. Default = 5,000 ms.
Reread Delay
This sets the time period before the scanner can read the same barcode a second
time. Setting a reread delay protects against accidental rereads of the same
barcode. Longer delays are effective in minimizing accidental rereads. Use shorter
delays in applications where repetitive barcode scanning is required. Reread Delay
only works when in a Presentation Mode (see page 19). Default = Medium.
* CodeGate Off
Out-of-Stand
CodeGate On
Out-of-Stand