Rev. 1.01 32 900.0570
8-Sept-05
HONEYWELL VCL PROTOCOL, CONTINUED
6.10.3 Remote Reset
Select RESET in the camera setup menu, then press ‘aux’ to display the reset menu as
shown below:
A U X = S E N D L O C K = E N D
P O W E R C A M E R A F A C T O R Y
6.10.3.1 Power Reset
To perform a power reset on the dome, select POWER in the reset menu, then press
‘aux’. The keyboard will be locked for 30 seconds whilst the dome resets, and the
following message will be displayed:
P O W E R U P R E S E T
6.10.3.2 Factory Reset
To perform a factory reset on the dome, select FACTORY in the reset menu, then press
‘aux’. The keyboard will be locked for 30 seconds whilst the dome resets, and the
following message will be displayed:
F A C T O R Y R E S E T
6.10.3.3 Camera Reset
To perform a camera reset on the dome, select CAMERA in the reset menu, then press
‘aux’. The keyboard will be locked for 12 seconds whilst the camera resets, and the
following message will be displayed:
C A M E R A R E S E T
6.10.4 Digital Zoom
Select ZOOM in the camera setup menu, then press ‘aux’ to display the zoom menu as
shown below:
A U X = S E T L O C K = E N D
D I G I T A L Z O O M O F F
Press ‘aux’ to toggle the digital zoom setting between OFF and ON’.