6 - 46
Global Tab
The settings on this panel can only be changed when an Admin is logged in with a password. The current values for the set-
tings can be viewed by the general user without requiring a password.
Note: Tap the Commit button to save changes. If the panel is exited before tapping the Commit button, changes are not
saved!
Setting Default
Roam Trigger -65 dBm
Roam Delta 5 dBm
Roam Period BG: 10 sec.
A: 5 sec.
BG Channel Set Full
DFS Channels Off
DFS Scan Time 120 ms.
Ad Hoc Channel 1
Aggressive Scan On
CCX BG: Off
A: Optimized
WMM
On
On
Off
Auth Server Type 1
TTLS Inner Method Auto-EAP
PMK Caching Standard
WAPI Off (dimmed)
TX Diversity BG: On
A: Main Only
RX Diversity BG: On-Start on Main
A: Main Only
Frag Threshold 2346
RTS Threshold 2347
LED Off
Tray Icon On
Hide Password On
Admin Password SUMMIT (or blank)
Auth Timeout 8 seconds
Certs Path C:\Program Files\Summit\certs
Ping Payload 32 bytes
Ping Timeout 5000 ms
Ping Delay ms 1000 ms
Logon Options Use SCU credentials