Fig. 1
5.2 Montere MightEvac til monteringsbra-
(se Fig. 1)
Trinn 1: Fjern de røde, runde, beskyttende klistremerkene fra begge sidene av MightEvac-enheten.
Trinn 2: Sett en festesvivel inn i braketten, slik som vist.
Trinn 3: Skyv enheten fremover inntil de gjengede hullene i huset (hvor klistremerkene ble fjernet) er
jamført med hullene i fronten av braketten, slik som vist.
MERK: Bærehåndtaket på enheten må være posisjonert oppover, vekk fra braketten.
Sett festet inn i låseskiven, avstandsstykket
og hullet i braketten. Stram til, til 8,
pluss eller minus 1 f lbs (96 pluss
eller minus 12 t lbs). Gjenta for
motsatt side.
Trinn 4: Før skyvestiften gjennom braketten
og inn i hullene. Dette vil gi sikkert
feste av enheten til braketten. Påse
at skyvestiften er helt gjennom
begge hull og blir værende
plass.
Trinn 5: Fest enheten med braketten til
et godkjent Miller forankringsele-
ment og fest med de medfølgende
skyvestiftene. Se installasjon-
sprosedyrene i avsnitt 5.3, 5.4, 5.5, 5.6 og 5.7 i dennendboken.
For å fjerne enheten, gjør ganske enkelt som motsatt av fremgangsmåten ovenfor.
5.0 Installasjon
For generelt fallvern kobler du redningslinens
endekobling (dvs. karabinkroken) til den bakre
D-ringen på kroppsseletøyet
MightEvac automatisk inntrekkbare redningsline
monteres på en overhengende forankring av
festesvivelen, ved bruk av en karabinlås eller andre
forankringskoblinger godkjent av Miller, eller den må
anvendes sammen med en monteringsbrakett fra Miller,
som deretter installereset trebent stativ (tripod).
Forankringen må ha kapasitet til å støtte en 22,2 kN
(5000 lbs) strekkbelastning. Gå gjennom alle advarsler
og instruksjoner når du skal velge et monteringssted.
FORANKRINGS-
KOBLING
KARABIN-
LÅSEKROK
FORANKRING
MAY RESULT IN SERIOUS OR FATALINJURY
WARNING! FAILURE TO OBSERVE INSTRUCTIONS
PAT. NO. 5,771,993
SELF-RET RAC TING LIFELI NE WI TH EME RGE NCY RE SCUE
®
• Always use and inspect unit in accordance
with manufacturer’s instructions.
• Do not use as a restraint or positioning
device.
• Use only with attachment fittings and safety
harness recommended by manufacture r.
• Always connect the hook directly to
attachment point on harness.
• Guard against swing falls by keeping the
lifeline vertically overhead. Never work
above the device.
• Keep user and other workers from becoming
entangled in lifeline.
• Do not allow lifeline to drag over
obstructions.
• Never clamp off or stand on the lifeline.
• Do not allow the lifeline to become slack.
• Do not allow cable, rope or webbing
lifelines to come in contact with anythin g
that will damage the lifeline including, but
not limited to, sharp, abrasive, rough or
high-temperature surfaces, welding, he at
sources, electrical hazards, or moving
machinery.
• Wear gloves when inspecting or handling
cable lifelines.
• Check lifeline for damage, frays, or cuts that
will reduce the strength.
• Maintain tension on the lifeline while letting
it retract after disconnecting from wo rker.
• Servicing must only be performed by the
manufacturer or an approved agent.
WARNI NG: Ma nufacturer ’s instru ctions supplied with t his pro duct at t ime of shipme nt must be foll owed: Failure t o do so could resul t in seriou s
injury o r death. Only for use by ONE person as a pers onal fall arrester. Device m ust b e taken out of servic e for ins pectio n and recertif ication
after arres ting a fa ll or when the imp act indicat or h as been ac tivated. Contact Miller Fall Protec tion if in struc tion manu al is ne eded.
ADVE RTENC IA: Deb en seguir se los instrucc iones del fabri cate pro vistas co n este producto al mome nto de d espach o: El no ha cerio
pued e resu ltar en les iones gr aves o la muert e. Sol o par a el uso po r UNA S OLA per sona co ma de tentor pe rsonal c ontra c aidas. El
dispos itivo d ebe retir arse d el servi cio pa ra ser in specc ionado y recer tificati on lue go de hab er deten ido una caida o cuand o se ha ya
activa do el indi cator de im pacto. Si se req uiere el manual d e instruc ciones consu lte con M iller Fa ll Prote ction.
ADVE RTISSEM EN T: Vou s devez respecter les i nstruct ions d u fabrican t que vo us avez recues avec le produit : Dans le cas
contrai re, vou s risque z de bles sures graves ou meme lamort. Utiliser seule ment pa r UNE pe rsonne co mme arr et de chute
person nelle. L’appareil doit etre mi s hors d ’utilisation p our insp ection et rec ertificati on apres avoir arrete un e chut e ou
lorsq ue l’indicateu r d’imp act a et e active. Co ntactez Miller F all Prot ection si vous av ez besoi n d’un nouvea u man uel.
LB388
Rev. D
MFP9350111
FESTESVIVEL
MIGHTEVAC MED MONTER-
INGSBRAKETT

Table of Contents

Related product manuals