42 UDACT Instruction Manual — P/N 50050:M 12/18/2009
Programming Instructions Ademco Contact ID Format
3.7.2 Secondary Number
If 'E' is entered for address 42, the following data is automatically programmed for the secondary phone
number event codes. Enter a '000' for the data setting to disable the report.
Table 3.7 Ademco Contact ID, Secondary Number
Address Description
Setting
1
Group #
2
Sensor #
139-141 Secondary# General Alarm Code 110 00 000
3
142-144 Secondary # Zone/Point Alarm Code
4
110
5
00 Note
6
145-147 Secondary # General Supervisory Code 200 00 000
3
148-150 Secondary # Zone/Point Supervisory Code
4
200 00 Note
6
151-153 Secondary # General Fault Code 300 00
154-156 Secondary # AC Fault Code 301 00
157-159 Secondary # Zone/Point Fault Code
4
380 00 Note
6
160-162 Secondary # Low Battery Fault Code 302 00
163-165 Secondary # Telco Primary Line Fault Code 351 00
166-168 Secondary # Telco Secondary Line Fault Code 352 00
169-171 Secondary # NAC Fault Code 321 00
172-174 Secondary # Comm. Trouble Primary # Code 354 00
175-177 Secondary # Comm. Trouble Secondary # Code 354 00
178-180 Secondary # 485 Comm. Trouble Code 300 00
181-183 Secondary # System Off Normal Code 308 00
184-186 Secondary # UDACT Off Normal Code 350 00
187-189 Secondary # System 24 Hour Test 602 00
190-192 Secondary # System 24 Hour Test w/active event 608 00
193-195 Secondary # Manual Test Message 601 00
196-198 Secondary # General Security Code
7
130 00 000
3
1 Zero entires prevent the transmission of the report to the Central Station.
2 The Group # is automatically incremented for AM2020/AFP1010, NFS2-3030, NFS-3030,
NCA-2 and NCA applications.
3 Refer to Contact ID program locations 64 - 68.
4 AFP-200 applications transmit by zone, not by point.
5 For control panels; System 500, System 5000, AFP-200, AFP-400, NFS2-640, NFS-640,
NFS-320, AFP1010, AM2020, NFS2-3030, NFS-3030, NCA-2, and NCA, the factory
default event code is 110 and reprogrammable. The AFP-400 and AFP-100 are unique in
point reporting mode in that only the control module report codes are programmable. The
factory setting of report code 111 is fixed for addressable smoke detectors and cannot be
changed.
6 The identification of the zone-device number is automatically transmitted by the UDACT
and is added to the main event code. See Table 5.3 for more information.
7 The General Security Code applies to UL 864 9th Edition-listed Control Panels only.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell NOTIFIER UDACT and is the answer not in the manual?

Honeywell NOTIFIER UDACT Specifications

General IconGeneral
BrandHoneywell
ModelNOTIFIER UDACT
CategoryCell Phone
LanguageEnglish

Related product manuals