36 EDA10A Enterprise Tablet User Guide
DPM mode Use this setting when scanning Direct Part Marking (DPM)
barcodes that are etched or imprinted directly into the surfaces of
materials including metal and plastic.
Options include:
No DPM optimization
Dotpeen DPM decoding
Reflective DPM decoding
No DPM
optimi-
zation
Region of Interest Set the ROI for decoding. Options include:
•Disable
ROI is disabled and the entire original image is sent to the
decoder.
•Standard
Use the aimer position to weight activity. Activity
calculated on the row and the column in the middle of
each cell. The ROI window may not include the aimer.
Standard, aimer centered
Activity calculated on the row and the column in the
middle of each cell. The ROI window will always include
the aimer.
DPM, aimer centered
Activity calculated on 4 rows and 2 columns in each cell.
The ROI window will always include the aimer.
Kiosk/presentation application
Ignore aimer position, no weight activity. Activity
calculated on the row and the column in the middle of
each cell. The ROI window may not include the aimer.
Learning Engine
When selected, the computer will receive continuous
updates to improve the decoder software based on your
specific environment. The Staging Hub Agent must also
be enabled.
Disabled
Setting Description Default