DescriptionDefault ValueRegistry Key
Length value L1. Range is 0x0 to 0xFF (0 to 255).0x6CodabarBarCodeLengthL1
Length value L2. Range is 0x0 to 0xFF (0 to 255).0x0CodabarBarCodeLengthL2
Length value L3. Range is 0x0 to 0xFF (0 to 255).0x0CodabarBarCodeLengthL3
Length verification mode, where 0 = "L1 is min length", 1 =
"L1, L2, L3 are fixed lengths", and 2 = "L1 is min, L2 is max
length".
0x0CodabarBarCodeLengthMode
Enable transmission of the check digit.0x0CodabarCheckDigitTransmission
Selects start/stop character format to transmit, where 0 =
not transmitted, 1 = "a, b, c, d", 2 = "A, B, C, D", 3 = "a, b,
c, d / t, n, *, e", and 4 = "DC1, DC2, DC3, DC4".
0x0CodabarStartStopTransmission
Enables the CLSI (Computer Library Services, Inc) library
standard for Codabar: 14 characters, no start/stop, spaces
at positions 2, 7, and 13.
0x0CodabarCLSILibrarySystem
Multiple label concatenation, where 0 = disabled, 1 = only
concatenated, and 2 = concatenate if possible.
0x0CodabarConcatenation
Sets requirements for concatenation, where 0 = no
requirements, 1 = Second code start = first code stop, and
0x0CodabarConcatenationMode
2 = American Blood Commission (second code start = first
code stop = 'd').
User-defined symbology identifier. Range is 0-4 characters."B7"CodabarUDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Code 93] - Code 93 Symbology Configuration
Enables the Code 93 symbology.0x0Code93Activation
A single character inserted before the barcode data to
indicate the symbology.
0x44Code93CodeMark
Length value L1. Range is 0x0 to 0xFF (0 to 255).0x1Code93BarCodeLengthL1
Length value L2. Range is 0x0 to 0xFF (0 to 255).0x0Code93BarCodeLengthL2
Length value L3. Range is 0x0 to 0xFF (0 to 255).0x0Code93BarCodeLengthL3
Length verification mode, where 0 = "L1 is min length", 1 =
"L1, L2, L3 are fixed lengths", and 2 = "L1 is min, L2 is max
length".
0x0Code93BarCodeLengthMode
User-defined symbology identifier. Range is 0-4 characters."B6"Code93UDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Code 39] - Code 39 Symbology Configuration
Enables the Code 39 symbology.0x1Code39Activation
Allows decoding of unconventional Code 39 (large
intercharacter spacing or a large ratio between narrow and
wide elements).
0x0Code39Unconventional
Confidential: For informational use by Honeywell resellers and customers only
Talkman A730 Symbologies | 67