50
53.MENU M8 - Technical calibration
This menu item is only to be used by the technician who installs the stove.
54.MENU M9 - Exit
Selecting this item by pressing P3 exits the menu and returns to the main screen.
55.ALARMS
If an operational anomaly occurs, the system notifies the user by turning on the alarms LED and issuing audible alarms.
The following alarms may occur:
Each alarm condition causes the stove to shut down immediately
The alarm status is reached after the PR11 time EXCEPT FOR THE BLACKOUT ALARM and can be reset by holding down the P3
button. Whenever an alarm is reset, a stove shutdown phase is started for safety. In the alarm phase, the alarms LED is always
on and where the buzzer is enabled, it will ring intermittently. Whenever the alarm is not reset the stove will shut off, always
showing the alarm message.
56.Power outage
During the stove operating status, there could be a power outage. If the blackout is for less than 5 seconds, the stove will
restart in OPERATION mode, otherwise the alarm sounds. The message "Al 1 alar al 1 Black-out" will scroll and the stove will
shut down
57.Smoke temperature probe alarm
This occurs if the smoke alarm is faulty. The stove goes into alarm status and the alarms LED is lit. The stove display will scroll
"Al 2 alar al 2 Smoke probe" and will shut down
Smoke overheating alarm
This occurs if the smoke probe detects a temperature that is greater than the set value and cannot be changed using the
parameter. The display shows "AL 3 alar al 3v Hot smoke" and the stove shuts down
58.Smoke encoder faulty alarm
This occurs if there is a smoke suction failure. The stove goes into alarm status and "Al 4 alar al 4 suction-fail" scrolls on the
display.
59.Failure to ignite alarm
This occurs when the ignition phase fails. This can happen if not enough pellets fall into the brazier or if the smoke temperature
does not go above the control value set in the technical parameters. The stove goes into alarm status and "Al 5 alar al 5 ignite
fail" scrolls on the display.