60.No pellets alarm
This occurs when the smoke temperature falls during operation due to the lack of pellets in the tank. The stove goes into alarm
status and "Al 6 alar al 6 no pellets" scrolls on the display.
61.Thermal safety overheating alarm
This occurs when the general safety thermostat detects a temperature greater than the threshold. The thermostat is tripped
and shuts down the screw feeder and the controller signals the alarm status (alarm LED on) scrolling "Al 7 alar al 7 thermal-
safe" and the stove shuts down.
62.No vacuum alarm
This occurs when the external pressure status component shows a pressure above the threshold (this may be do to a clogged
flue or wind gusts). The pressure switch is tripped, shutting down the screw feeder, since it is electrically connected, and the
controller signals the alarm status (alarm LED on) showing "Al 8 alar al 8 No vacuum". The stove goes into shutdown mode
63.TROUBLESHOOTING
Problem
Cause
Solution
The stove does not
ignite
Power disconnected\switch off
Protective fuse tripped
Connect the power cable and/or turn on the
switch
Check the fuse located in the switch
It is inside the control board
The stove loads
pellets but there is
no flame
Igniter not working
Brazier clogged with residues
from
combustion.
Brazier inserted incorrectly
Replace the igniter
Empty the brazier and clean it, check and clean
the brazier support and the combustion
chamber
Reposition the brazier
The stove ignites
but during
operation goes
immediately into
modulation
(minimum power)
Room probe faulty or
regulated with temperature
less than the room
temperature
Remote thermostat (if
connected and set) faulty or
regulated with temperature
Check the probe status or set with a value
greater than the actual room temperature
Check the thermostat operation (if the
outdoor thermostat is the battery powered
type, check the batteries) or set with a value
greater than the actual room temperature