Manuale di installazione uso e
manutenzione
52
less than the room
temperature
The stove shows a
blackout
No power
Plug improperly connected
Check the connections on both the mains and
the stove, check (AFTER UNPLUGGING THE
POWER CORD) proper operation of the switch,
hookups, and terminals
The stove shows
"Smoke
temperature
probe"
Smoke temperature control
probes deteriorated
Contact technical assistance
The stove shows
"Smoke
overheating"
Poor exhaust
The room fan is blocked or
clogged with dust
Check the smoke evacuation airways (flues,
chimneypots)
Check the fan operation, clean any excessive ash
incrustations, and replace if broken.
Contact technical assistance
The stove shows
"Smoke Encoder
faulty"
The control board cannot
control the smoke exhaust
speed
Smoke exhaust motor
blocked.
Make sure the motor has no mechanical
problems (ash accumulations, bearing partially
blocked, combustion chamber door open),
check, clean, replace
Check the motor, check for any ash
accumulations on the internal impeller
Contact technical assistance
The stove shows
"Ignition fail"
No pellets in the tank
Too much ash residue in the
brazier
Igniter malfunctioning
Refill the fuel tank
Empty and clean the brazier, clean any clogged
air holes, check the condition of the brazier
Check the terminals, electrical operation, and
replace if not working
Contact technical assistance