Component identification 16
The drive is rebuilding or performing a RAID migration, strip size
migration, capacity expansion, or logical drive extension, or is
erasing.
amber/green
The drive is a member of one or more logical drives and predicts
the drive will fail.
The drive is not configured and predicts the drive will fail.
The drive is not configured by a RAID controller.
The blue Locate LED is behind the release lever and is visible when illuminated.
IMPORTANT:
The Dynamic Smart Array B140i Controller is only available in UEFI Boot Mode.
It cannot be enabled in Legacy BIOS Boot Mode. If the B140i controller is disabled, drives
connected to the system board Mini-SAS connectors operate in AHCI or Legacy mode. Unde
this condition:
• The drives cannot be a part of a hardware RAID or a logical drive.
• The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.
Use BIOS/Platform Configuration (RBSU) in the UEFI System Utilities ("HPE UEFI System
Utilities" on page 98) to enable or disable the B140i controller (System Configuration →
BIOS/Platform Configuration (RBSU) → System Options → SATA Controller Options →
Embedded SATA Configuration).
Fan locations