Operations 24
o
Slide the server into the rack.
o Install the server into the rack ("Installing the server into the rack" on page 30).
5. Power up the server (on page 17).
Remove the air baffle
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components,
minimize the amount of time the access panel is open.
To remove the component:
1. If installed, remove the security bezel (on page 17).
2. Power down the server (on page 17).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Do one of the following:
o Extend the server from the rack (on page 18).
o Remove the server from the rack (on page 19).
5. Remove the access panel (on page 20).
6. Remove the air baffle.
To replace the component, reverse the removal procedure.
Install the air baffle
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components,
minimize the amount of time the access panel is open.