Hardware options installation 71
NOTE: If expansion board installed with full-height support bracket, replace with low-profile
support bracket in the expansion board kit.
o Slot 1
o Slot 2
9. Connect all necessary internal cabling to the expansion board. For more information on these
cabling requirements, see the documentation that ships with the option.
10. Install the PCI riser cage (on page 23).
CAUTION: To prevent improper cooling and thermal damage, do not operate the server
unless all PCI slots have either an expansion slot cover or an expansion board installed.
11. Install the access panel (on page 21).
12. Do one of the following:
o Slide the server into the rack.
o Install the server into the rack ("Installing the server into the rack" on page 30).
13. Connect each power cord to the server.
14. Connect each power cord to the power source.
15. Power up the server (on page 17).
16. If removed, install the security bezel ("Security bezel option" on page 36).
Redundant power supply option