Hardware options installation 77
c.
Secure the power cord with the strain relief strap.
16. Employ best practices to route and manage the power cords and other cables in the server rear
panel.
IMPORTANT: When using cable management arm components, be sure to leave enough
slack in each of the cables to prevent damage to the cables when the se
the rack.
17. If removed, install the Smart Storage Battery holders ("Installing an HPE Smart Storage Battery" on
page 48).
18. If removed, install the Smart Storage Battery and connect the cable to the system board ("Installing
an HPE Smart Storage Battery" on page 48).
19. Install the air baffle (on page 24).
20. Install the access panel (on page 21).
21. Do one of the following:
o Slide the server into the rack.
o Install the server into the rack ("Installing the server into the rack" on page 30).
22. Connect each power cord to the server.
23. Connect each power cord to the power source.
24. Power up the server (on page 17).
25. If removed, install the security bezel ("Security bezel option" on page 36).
HPE Trusted Platform Module option
For more information about product features, specifications, options, configurations, and compatibility,
see the product QuickSpecs on the Hewlett Packard Enterprise website (http://www.hpe.com/info/qs).
Use these instructions to install and enable a TPM on a supported server. This procedure includes three
sections:
1. Installing the Trusted Platform Module board (on page 78).
2. Retaining the recovery key/password (on page 79).
3. Enabling the Trusted Platform Module (on page 80).
Enabling the TPM requires accessing BIOS/Platform Configuration (RBSU) in UEFI System Utilities
("HPE UEFI System Utilities" on page 98).