Component identification 15
LED
Status
Definition
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
IMPORTANT:
The Dynamic Smart Array B140i Controller is only available in UEFI Boot Mode.
It cannot be enabled in Legacy BIOS Boot Mode. If the B140i controller is disabled, drives
connected to the system board Mini-SAS connectors operate in AHCI or Legacy mode. Unde
r
this condition:
The drives cannot be a part of a hardware RAID or a logical drive.
The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.
Use BIOS/Platform Configuration (RBSU) in the UEFI System Utilities ("HPE UEFI System
Utilities" on page 82) to enable or disable the B140i controller (System Configuration
BIOS/Platform Configuration (RBSU) System Options SATA Controller Options
Embedded SATA Configuration).
Fan locations
Fan number
Fan type
1
System fan
2
Front PCI fan (optional)