129
Power Priority : Critical
Oper : On
IEEE Class : 1
Detection Status : Delivering power
Power Mode : Signal
Current Power : 11592 mW
Average Power : 11610 mW
Peak Power : 11684 mW
Max Power : 15400 mW
Electric Current : 244 mA
Voltage : 51.7 V
PD Description : IP Phone For Room 101
Table 22 Command output
Field Description
PoE status
PoE status:
• Enabled.
• Disabled.
Power Priority
Power supply priority of the PI:
• Critical (highest).
• High.
• Low.
Oper
Operating status of a PI:
• Off—PoE is disabled.
• On—Power is being supplied to the PI correctly.
• Power-lack—Remaining guaranteed power is insufficient for a critical
PI.
• Power-deny—The PSE refuses to supply power. The power required
by the PD is higher than the configured power.
• Power-itself—The PD is using another power supply.
• Power-limit—The PSE is supplying power to the PD based on the
configured power though the PD requires more power than the
configured power.
IEEE Class
PD power class: 0, 1, 2, 3, or 4.
If the PSE does not support PD classification, this field displays a hyphen
(-).
Detection Status
Power detection status of a PI:
• Disabled—The PoE function is disabled.
• Searching—The PI is searching for the PD.
• Delivering power—The PI is supplying power to the PD.
• Fault—A fault occurred during the test.
• Test—The PI is undergoing a test.
• Other fault—A fault has caused the PSE to enter the idle status.
• PD disconnected—The PD is disconnected.