129
Power Priority : Critical
Oper : On
IEEE Class : 1
Detection Status : Delivering power
Power Mode : Signal
Current Power : 11592 mW
Average Power : 11610 mW
Peak Power : 11684 mW
Max Power : 15400 mW
Electric Current : 244 mA
Voltage : 51.7 V
PD Description : IP Phone For Room 101
Table 22 Command output
Field Description
PoE status
PoE status:
Enabled.
Disabled.
Power Priority
Power supply priority of the PI:
Critical (highest).
High.
Low.
Oper
Operating status of a PI:
Off—PoE is disabled.
On—Power is being supplied to the PI correctly.
Power-lack—Remaining guaranteed power is insufficient for a critical
PI.
Power-deny—The PSE refuses to supply power. The power required
by the PD is higher than the configured power.
Power-itself—The PD is using another power supply.
Power-limit—The PSE is supplying power to the PD based on the
configured power though the PD requires more power than the
configured power.
IEEE Class
PD power class: 0, 1, 2, 3, or 4.
If the PSE does not support PD classification, this field displays a hyphen
(-).
Detection Status
Power detection status of a PI:
Disabled—The PoE function is disabled.
Searching—The PI is searching for the PD.
Delivering power—The PI is supplying power to the PD.
Fault—A fault occurred during the test.
Test—The PI is undergoing a test.
Other fault—A fault has caused the PSE to enter the idle status.
PD disconnected—The PD is disconnected.