130
Field Description
Power Mode
Power transmission mode of a PI:
Signal—Power is being supplied over signal cables.
Spare—Power is being supplied over spare cables.
Current Power
Current power of a PI, including PD consumption power and transmission
loss.
Typical transmission loss is within 1 watt.
Average Power Average power of a PI.
Peak Power Peak power of a PI.
Max Power Maximum power of a PI.
Electric Current Current of a PI.
Voltage Voltage of a PI.
PD Description Type and location description for the PD connected to the PI.
# Display power supplying information for all PIs.
<Sysname> display poe interface
Interface PoE Priority CurPower Oper IEEE Detection
(W) Class Status
GE2/0/1 Enabled Low 4.4 On 1 Delivering Power
GE2/0/2 Enabled Critical 0.0 On - Disabled
GE2/0/3 Enabled Low 0.0 On - Disabled
GE2/0/4 Enabled Critical 0.0 On - Searching
GE2/0/5 Enabled Low 4.0 On 2 Delivering Power
GE2/0/6 Enabled Low 0.0 On - Disabled
GE2/0/7 Disabled Low 0.0 Off - Fault
--- On State Ports: 2; Used: 8.4(W); Remaining: 171.6(W) ---
Table 23 Command output
Field Description
Interface Interface name of a PI.
PoE
PoE status:
Enabled.
Disabled.
Priority
Power priority of a PI:
Critical (highest).
High.
Low.
CurPower Current power of a PI.

Table of Contents