13 Specications
This section provides specications for your computer.
Table 13-1 Specications
Metric U.S.
Dimensions
Width 270 mm 10.6 in
Depth 303 mm 11.9 in
Height 95 mm 3.7 in
Approximate weight 3.9 kg 8.6 lb
Temperature range
Operating 5° to 35°C 41° to 95°F
Nonoperating –30° to 60°C –22°F to 140°F
NOTE: Operating temperature is derated 1.0°C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight.
Maximum rate of change is 10° C/Hr. The upper limit might be limited by the type and number of options installed.
Maximum altitude (unpressurized)
Operating 5,000 m 16,404 ft
Nonoperating 15,240 m 50,000 ft
Relative humidity (noncondensing)
Operating 5% to 90%
Nonoperating (38.7°C max wet bulb) 5% to 90%
Power supply
Operating voltage range 90 Vac to 264 Vac
Rated voltage range
1
100 Vac to 240 Vac
Rated line frequency 50 Hz to 60 Hz
Operating line frequency 47 Hz to 63 Hz
Standard eciency 65 W, 87% ecient
1
This system uses an active power factor-corrected power supply. This allows the system to pass the CE mark requirements for use in the
countries of the European Union. The active power factor-corrected power supply also has the added benet of not requiring an input-
voltage range select switch.
ENWW 123