Removal and replacement procedures 36
2.
Remove the power from the server:
a. Disconnect the power cord from the power source.
b. Disconnect the power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 29).
o Remove the server from the rack (on page 30).
4. Open the access panel latch, slide the access panel to the rear of the chassis, and then remove the
access panel.
If the access panel latch is locked, use a T-15 Torx screwdriver to unlock the latch.
To replace the component, reverse the removal procedure.
Air baffle
To remove the component:
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
1. Power down the server (on page 28).
2. Remove the power from the server:
a. Disconnect the power cord from the power source.
b. Disconnect the power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 29).
o Remove the server from the rack (on page 30).
4. Remove the access panel ("Access panel" on page 35).
5. Remove the air baffle.