EasyManua.ls Logo

HP ProLiant DL320e Gen8 v2 - Dimms

HP ProLiant DL320e Gen8 v2
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal and replacement procedures 44
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To remove the component:
1. Power down the server (on page 28).
2. Remove the power from the server:
a. Disconnect the power cord from the power source.
b. Disconnect the power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 29).
o Remove the server from the rack (on page 30).
4. Remove the access panel ("Access panel" on page 35).
5. Remove the air baffle ("Air baffle" on page 36).
6. Disconnect the fan cables.
7. Remove the fan cage.
To replace the component, reverse the removal procedure.
DIMMs
To remove the component:
1. Power down the server (on page 28).
2. Remove the power from the server:
a. Disconnect the power cord from the power source.
b. Disconnect the power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 29).
o Remove the server from the rack (on page 30).

Table of Contents

Other manuals for HP ProLiant DL320e Gen8 v2

Related product manuals