HP ProLiant DL380 G5 - Front Panel Controls and Indicators

HP ProLiant DL380 G5
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
gl0070
1 2 3 4 5 6
Figure 3 Front panel controls and indicators
Table 3 Front panel controls and indicators
Item
Description Status
1
UID LED but
ton
Blue = Acti
vated
Flashing =
System being remotely managed
Off=Deactivated
2
Internal health LED Green = Normal
Amber = System degraded. To identify components in degraded
state, see "System Insight Display LEDs"onpage27.
Red = System critical. To identify components in critical state, see
"System Insight Display LEDs "onpage27.
3
External health LED (power
supply)
Green = Normal
Amber = Power redundancy failure. To identify components in
degraded state, see "System Insight Display LEDs"onpage27.
Red = Critical power supply failure. To identify component in critical
state, see Systems Insight Display LEDs.
4
NIC 1 link/activity LED
Green = N
etwork link
Flashin
g=Networklinkandactivity
Off = No link to network. If power is off, view the rear panel RJ-45
LEDs for status.
5
NIC 2 link/activity LED
Green = Network link
Flashing = Net work link and activity
Off = No link to network. If power is off, view the rear panel RJ-45
LEDs for status.
6
Power On/Standby
button/system power
LED
Green = System on
Amber = System shut down, but power still applied
Off = Power cord not attached or power supply failure