8. Install the drive cage.
9. Route and connect the cables depending on the server configuration. For more information, see
"Cabling on page 109."
To cable the drive cage to the HPE 12G SAS Expander, see "Installing the HPE 12G SAS Expander
Card on page 96."
10. If removed, do the following:
a. Install the air baffle (Installing the air baffle on page 43).
b. Install the processor mezzanine tray (Installing a processor mezzanine tray on page 87).
c. Install the 2P pass-through performance board (Installing a 2P pass-through performance board
on page 88).
11. Install the fan cage.
12. Install the access panel (Installing the access panel on page 41).
13. Install the server into the rack (Installing the server into the rack on page 34).
14. Connect each power cord to the server.
15. Connect each power cord to the power source.
16. Power up the server (Powering up the server on page 38).
Installing a universal media bay
Prerequisites
Before installing this option, be sure that you have the following:
• The components included with the hardware option kit
• T-10 Torx screwdriver
Procedure
1. Power down the server (Power down the server on page 38).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
56 Installing a universal media bay