To install the component:
Prerequisites
Before installing this option, be sure that you have the following:
• T-10 Torx screwdriver
• The components included with the hardware option kit
Procedure
1. Power down the server (Power down the server on page 38).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
• Extend the server from the rack (Extend the server from the rack on page 38).
• Remove the server from the rack (Removing the server from the rack on page 39).
4. Remove the access panel (Removing the access panel on page 40).
5. If installed, do the following:
a. Remove the air baffle (Removing the air baffle on page 42).
b. Remove the processor mezzanine tray (Removing the processor mezzanine tray on page 47).
c. Remove the 2P pass-through performance board (Removing the 2P pass-through performance
board on page 48).
6. Remove the fan cage (Removing the fan cage on page 46).
7. Remove the screws, and then remove the drive bay blank.
8. Remove the optical disk drive tray from the universal media bay.
Installing hardware options 59