Edge Switch 2/24 installation guide 67
3 Using the Embedded Web Server
If an HAFM appliance is not available, or is not used to manage the switch, use the Embedded
Web Server (EWS) interface to configure the Edge Switch 2/24. Selectively perform the following
configuration tasks according to your installation requirements:
• Configure switch ports, page 68
• Configure switch and fabric parameters, page 71
• Configure network information, page 74
• Configure SNMP trap message recipients, page 76
• Enable or disable the CLI, page 77
• Configure user rights, page 78
NOTE: This chapter describes the initial setup of the Edge Switch 2/24 using the EWS interface.
For additional information on configuring more advanced features using EWS, see the online EWS
help or the HP StorageWorks Embedded Web Server user guide.
Accessing the Embedded Web Server
A PC platform with LAN access and standard web browser running Netscape Navigator 4.6 or
later or Microsoft Internet Explorer 4.0 or later is required.
To open the Embedded Web Server interface:
1. Ensure that the browser-capable PC and the Ethernet LAN segment (with the switch attached) are
connected.
2. At the PC, launch the browser application (Netscape Navigator
or Internet Explorer).
3. At the browser, enter the IP address of the switch as the Internet uniform resource locator (URL).
Use the default IP address of 10.1.1.10, the factory preset of 10.1.1.10, or the IP address
configured while performing ”Configure network information” on page 74. The Enter Network
Password dialog box is displayed, as shown in Figure 34.
Figure 34 Enter Network Password dialog box