EasyManua.ls Logo

HP Storevirtual 4000 - Summary of NIC Status During Failover; Which Physical Interface Is Preferred

HP Storevirtual 4000
282 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Requirements for Active-Passive
To configure Active-Passive:
Both NICs should be enabled.
NICs should be connected to separate switches.
Which physical interface is preferred
When the Active-Passive bond is created, if both NICs are plugged in, the SAN/iQ software
interface becomes the active interface. The other interface is Passive (Ready).
For example, if Motherboard:Port1 is the preferred interface, it will be active and Motherboard:Port2
will be Passive (Ready). Then, if Motherboard:Port1 fails, Motherboard:Port2 changes from Passive
(Ready) to active. Motherboard:Port1 changes to Passive (Failed).
Once the link is fixed and Motherboard:Port1 is operational, there is a 30–second delay and then
Motherboard:Port1 becomes the active interface. Motherboard:Port2 returns to the Passive (Ready)
state.
NOTE: When the active interface comes back up, there is a 30–second delay before it becomes
active.
Table 19 Example Active-Passive failover scenario and corresponding NIC status
NIC statusExample failover scenario
1. Active-Passive bond0 is created. The active (preferred)
interface is Motherboard:Port1.
Bond0 is the master logical interface.
Motherboard:Port1 is Active.
Motherboard:Port2 is connected and is Passive (Ready).
2. Active interface fails. Bond0 detects the failure and
Motherboard:Port2 takes over.
Motherboard:Port1 status becomes Passive (Failed).
Motherboard:Port2 status changes to Active.
3. The Motherboard:Port1 link is restored.
Motherboard:Port1 status changes to Active after a 30
second delay.
Motherboard:Port2 status changes to Passive (Ready).
Summary of NIC status during failover
shows the states of Motherboard:Port1 and Motherboard:Port2 when configured for Active-Passive.
Table 20 NIC status during failover with Active-Passive
Status of Motherboard:Port2Status of Eth0Failover status
Preferred: NoPreferred: YesNormal Operation
Status: Passive (Ready)Status: Active
Data Transfer: NoData Transfer: Yes
Preferred: NoPreferred: YesMotherboard:Port1 Fails, Data
Transfer Fails Over to
Motherboard:Port2
Status: Active
Data Transfer: Yes
Status: Passive (Failed)
Data Transfer: No
Preferred: NoPreferred: YesMotherboard:Port1 Restored
Status: Passive (Ready)Status: Active
Data Transfer: NoData Transfer: Yes
Configuring network interface bonds 55

Table of Contents

Other manuals for HP Storevirtual 4000