Screen Message Probable Cause Recommended Action
914–Hood Lock Coil is not
Connected
Hood lock mechanism is missing or
not connected.
1. Reconnect or replace the hood locking
mechanism.
2. Reseat or replace the hood locking mechanism
cable.
915–Fan Power from Power
Supply Not Connected
The fan power cable is not connected,
or the power supply is bad.
CAUTION Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
1. Verify that all power supply cables are connected.
2. Replace the power supply.
916–Power Button Not
Connected
The power button is not connected.
CAUTION Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Connect the power button.
917–Front Audio Not
Connected
The front audio cable is not connected.
CAUTION Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Connect the front audio cable.
918–Front USB Not Connected Front USB is not connected.
CAUTION Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Connect the front USB cable.
921–Device in PCI Express
Slot Failed to Initialize
A PCI Express card was detected in
one of the slots, but failed to initialize
properly.
CAUTION Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Reseat all PCI Express cards. If this failure occurred
after inserting a new card, there could be a problem with
that card.
922–Fatal error on slot # Fatal error occurred in the designated
slot.
CAUTION Disconnect AC power from the
workstation before reseating or replacing
components because there is power to the
system board even when the workstation is
powered down.
Try moving card to a different slot. If the problem
persists, try replacing the card.
Table 5-18 POST error messages (continued)
136 Chapter 5 System diagnostics and troubleshooting ENWW