33
Figure 28 SFP+ network cable
(1) Connector
(2) Pull latch
NOTE:
As a best practice, use only HPE SFP/SFP+ transceiver modules and SFP+ network cables for
the SFP+ ports.
The SFP/SFP+ transceiver modules and SFP+ network cables available for the switch are
subject to change over time. For the most up-to-date list of SFP/SFP+ transceiver modules and
SFP+ network cables, consult your Hewlett Packard Enterprise sales representative or technical
support engineer.
For the specifications for the HPE SFP/SFP+ transceiver modules and SFP+ network cables,
see HPE Comware-Based Devices Transceiver Modules User Guide.
LEDs
Table 17 HPE 1950 12XGT 4SFP+ Switch LEDs at a glance
LED
Remarks
System status LED
See Table 18.
RPS status LED
See Table 19.
Management Ethernet port LED
See Table 20.
1/10GBASE-T autosensing Ethernet port LED
See Table 21.
SFP+ port LED
See Table 22.
System status LED
The system status LED shows the operating state of the switch.
Table 18 System status LED description
LED mark
Status
Description
SYS
Steady green
The switch is operating correctly.
Flashing green (1 Hz)
The switch is performing power-on self test (POST).
Steady red
The switch has failed the POST or is faulty.
1
2

Table of Contents