34
LED mark
Status
Description
Flashing yellow (1 Hz)
Some ports have failed to pass POST or are faulty.
Off
The switch is powered off.
RPS status LED
The switch supports RPS input. The RPS status LED shows the status of the RPS input.
Table 19 RPS status LED description
LED mark
Status
Description
RPS
Steady green
Both the RPS DC input and the AC input are normal.
Steady yellow
The RPS DC input is normal, but the AC input is disconnected or
has failed.
Off
The RPS DC input is abnormal or no RPS is connected.
Management Ethernet port LEDs
Each switch provides a management Ethernet port LED to indicate the operating state of the
management Ethernet port.
Table 20 Management Ethernet port LED description
Management Ethernet
port LED (MGMT) status
Description
Steady green
A link is present on the port and the port is operating at 1000 Mbps.
Flashing green
The port is sending or receiving data at 1000 Mbps.
Steady yellow
A link is present on the port and the port is operating at 10/100 Mbps.
Flashing yellow
The port is sending or receiving data at 100 or 10 Mbps.
Off
No link is present.
1/10GBASE-T autosensing Ethernet port LED
Table 21 1/10GBASE-T autosensing Ethernet port LED description
1/10GBASE-T autosensing Ethernet
port LED status
Description
Steady green
A link is present on the port and the port is operating at 10
Gbps.
Flashing green
The port is sending or receiving data at 10 Gbps.
Steady yellow
A link is present on the port and the port is operating at 1
Gbps.
Flashing yellow
The port is sending or receiving data at 1 Gbps.
Flashing yellow (3 Hz)
The port has failed POST.