19. Install the front bezel .
ResultsResults
The installation is complete.
Installing the 4 SFF NVMe drive cage optionInstalling the 4 SFF NVMe drive cage option
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
About this taskAbout this task
This server supports several 4 SFF NVMe drive cage options with different backplanes.
2 SFF 24G x4 U.3 NVMe / SAS UBM3 BC
2 SFF 24G x4 U.3 NVMe / SAS UBM6 BC
For more information on the drive backplane description, see Drive backplane naming convention .
CAUTION:CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-
sensitive devices. To prevent damage, observe antistatic precautions.
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.
ProcedureProcedure
1. Back up all server data.
2. If installed, remove the front bezel .
3. Power down the server.
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Disconnect all peripheral cables from the server.
6. Remove the server from the rack.
7. Place the server on a flat, level work surface.
8. Remove the access panel .
9. Remove the middle cover .
10. Disconnect the following cables from the system board:
8 E3.S drive controller cables
Drive power cable
11. Remove the 8 E3.S drive cage:
a. Remove the screw.
b. Rotate the locking pin to the open (vertical) position.
c. Remove the drive cage.
HPE ProLiant DL325 Gen11 Server User Guide 100