The riser cage is aligned with the rear chassis.
The riser board is firmly seated on the system board.
b. Simultaneously push and rotate the half-turn spring latch to 180°.
c. Close the spring latch.
10. Install the access panel .
11. Install the server into the rack.
12. Connect all peripheral cables to the server.
13. Connect the power cords:
a. Connect each power cord to the server.
b. Connect each power cord to the power source.
14. Power up the server.
ResultsResults
The installation is complete.
Installing the NS204i-u + secondary low-profile riser cageInstalling the NS204i-u + secondary low-profile riser cage
About this taskAbout this task
CAUTION:CAUTION:
To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or
replacement procedure. Improper grounding can cause electrostatic discharge.
ProcedureProcedure