CAUTION:CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-
sensitive devices. To prevent damage, observe antistatic precautions.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Remove the server from the rack.
5. Place the server on a flat, level work surface.
6. Remove the access panel .
7. Install the chassis intrusion detection switch:
a. Insert the switch tab into the chassis slot until the switch clicks into place.
b. Connect the switch cable and secure it in the cable clamp.
8. Install the access panel .
9. Install the server into the rack.
10. Connect all peripheral cables to the server.
11. Connect the power cords:
a. Connect each power cord to the server.
b. Connect each power cord to the power source.
12. Power up the server.
ResultsResults
The installation is complete.
HPE ProLiant DL325 Gen11 Server User Guide 181