Chassis 12 flashes
GPU card 13 flashes
SubsystemSubsystem LED behaviorLED behavior
Systems Insight Display LEDsSystems Insight Display LEDs
The Systems Insight Display LEDs represent the system board layout. The display enables diagnosis with the access panel installed.
DescriptionDescription StatusStatus
Processor LEDs Off = Normal
Amber = Failed processor
DIMM LEDs Off = Normal
Amber = Failed DIMM or configuration issue
DIMM group LEDs Off = Normal
Amber = Failed DIMM or configuration issue
Fan LEDs Off = Normal
Amber = Failed fan or missing fan
NIC LEDs Off = No link to network
Solid green = Network link
Flashing green = Network link with activity
If power is off, the front panel LED is not active. For status, see Rear panel LEDs.
Power supply LEDs Off = Normal
Solid amber = Power subsystem degraded, power supply failure, or input power lost.
PCI riser LED Off = Normal
Amber = Incorrectly installed PCI riser cage
Over temp LED Off = Normal
Amber = High system temperature detected
Power cap LED Off = System is in standby, or no cap is set.
Solid green = Power cap applied
1