The components included with the hardware option kit
T-10 Torx screwdriver
ProcedureProcedure
1. Observe the following alerts:
WARNING:WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION:CAUTION: To prevent damage to electrical components, properly ground the server before beginning any
installation procedure. Improper grounding can cause electrostatic discharge.
2. Back up all server data.
3. Power down the server .
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
6. Remove the access panel .
7. Remove the SID blank.
8. Guide the SID cable through the front of the server.