SpecificationsSpecifications ValueValue
Temperature range*Temperature range*
Operating 10°C to 35 °C (50°F to 95°F)
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)Relative humidity (noncondensing)
Operating 8% to 90%
28°C (82.4°F) maximum wet bulb temperature
Nonoperating 5 to 95%
38.7°C (101.7°F) maximum wet bulb temperature
AltitudeAltitude
Operating 3050 m (10,000 ft). This value may be limited by the type and number of options installed.
Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Nonoperating 9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Standard operating supportStandard operating support
10°C to 35°C (50°F to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20°C/hr (36°F/hr). The upper limit and rate of
change may be limited by the type and number of options installed.
System performance during standard operating support may be reduced if operating above 30°C (86°F).
Extended ambient operating supportExtended ambient operating support
For approved hardware configurations, the supported system inlet range is extended to be:
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per
every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft).
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m
(2953 ft) to a maximum of 3050 m (10,000 ft).
The approved hardware configurations for this system are listed on the Extended Ambient Temperature Guidelines for Gen10 Plus HPE
ProLiant and HPE Apollo servers and HPE Synergy:
https://www.hpe.com/support/ASHRAEGen10_Plushttps://www.hpe.com/support/ASHRAEGen10_Plus
System performance might be reduced if operating in the extended ambient operating range.
Mechanical specificationsMechanical specifications
DimensionDimension ValueValue
Height 11.89 cm (4.68 in)
Depth 24.50 cm (9.65 in)
Width 24.50 cm (9.65 in)
Weight, minimum (one drive and one DIMM
installed, no iLO enablement module or expansion
card installed)
4.82 kg (10.63 lb)
Weight, maximum (four drives, two DIMMs, iLO
enablement module, and an expansion card
installed)
7.20 kg (15.87 lb)