CAUTION: For proper cooling, do not operate the server without the access panel, bales, expansion slot covers, or
blanks installed. If the server supports hot-plug components, minimize the amount of time the access panel is open.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any
installation procedure. Improper grounding can cause electrostatic discharge.
Procedure
1.
Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripherals cables from the server.
4. If a Kensington security cable is installed, disconnect it from the rear panel. See the security cable documentation for
instructions.
5.
Do one of the following:
• Server in rack mode:
Remove the server from the rack.
• Server in tower mode:
Position the tower server for hardware configuration.
6.
Remove the access panel:
a.
Loosen the access panel thumbscrews.
b.
Slide and remove the access panel from the server.
Operations
27