20. Connect each power cord to the server.
21. Connect each power cord to the power source.
22.
Power up the server.
The installation is complete.
Installing the eight-bay SFF hot-plug drive cage
The eight-bay SFF hot-plug drive cage can be installed in both box 1 and box 2.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
• Eight-bay SFF hot-plug drive cage option
• SFF hot-plug drive option
• T-15 Torx Screwdriver
Procedure
1.
Power down the server.
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Disconnect all peripheral cables from the server.
4.
Do one of the following:
• Server in rack mode:
Remove the server from the rack.
• Server in tower mode: Position the tower server for hardware configuration.
5.
Remove the access panel.
6.
Remove the front bezel.
7.
Remove the PCI air bale.
8.
Remove the system air bale.
9. Disconnect all existing drive cage cables.
10. Remove the installed drive cage assembly.