SubtopicsSubtopics
Preparing the server for storage controller installationPreparing the server for storage controller installation
Installing the type-p storage controllerInstalling the type-p storage controller
Installing the type-o storage controllerInstalling the type-o storage controller
Preparing the server for storage controller installationPreparing the server for storage controller installation
PrerequisitesPrerequisites
Before beginning this procedure, download the Service Pack for ProLiant (SPP) from the Hewlett Packard Enterprise website
(https://www.hpe.com/servers/spp/downloadhttps://www.hpe.com/servers/spp/download).
ProcedureProcedure
1. If the server was previously configured:
a. Back up data on the system .
b. Close all applications.
c. Ensure that users are logged off and that all tasks are completed on the server.
CAUTION:CAUTION: In systems that use external data storage, be sure that the server is the first unit to be powered down and
the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the drives as
failed when the server is powered up.
2. If the server firmware is not the latest revision, update the firmware.
3. If the new controller is the new boot device, install the controller drivers .
Installing the type-p storage controllerInstalling the type-p storage controller
PrerequisitesPrerequisites
To enable the flash-backed write cache (FBWC) feature of a storage controller option, install an energy pack.
For more information on the controller caching feature, see the controller QuickSpecs on the Hewlett Packard Enterprise website
(https://www.hpe.com/info/qshttps://www.hpe.com/info/qs).
Before you perform this procedure, make sure that you have the following items available:
Compatible controller cable
T-15 Torx screwdriver
About this taskAbout this task
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all PCIe slots have either a
riser slot blank or an expansion card installed.
CAUTION:CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-
sensitive devices. To prevent damage, observe antistatic precautions.
ProcedureProcedure
1. Back up all server data.
HPE ProLiant ML110 Gen11 Server User Guide 123