Description Chassis Number of LFF/SFF/NVMe
drives that correspond to
the server
Maximum inlet ambient
temperature
HPE Smart Array
P408i-p Controller
1
Apollo r2800
Gen10 Chassis
with 16 NVMe
0 to 4 drives This configuration is not
supported
HPE Smart Array
P408e-p
Controller
1
Apollo r2200
Gen10 Chassis
3 drives 22°C (71.6°F)
Apollo r2200
Gen10 Chassis
0 to 2 drives
2
30°C (86°F)
Apollo r2600
Gen10 Chassis
0 to 6 drives 30°C (86°F)
Apollo r2800
Gen10 Chassis
with SAS Expander
0 to 24 drives 30°C (86°F)
Apollo r2800
Gen10 Chassis
with 16 NVMe
0 to 4 drives 30°C (86°F)
HPE Smart Array
E208e-p
Controller
3
Apollo r2200
Gen10 Chassis
3 drives 30°C (86°F)
Apollo r2200
Gen10 Chassis
0 to 2 drives
2
35°C (95°F)
Fibre channel host
bus adapter
Apollo r2200
Gen10 Chassis
3 drives This configuration is not
supported.
Apollo r2200
Gen10 Chassis
0 to 2 drives
2
28°C (82.4°F)
Apollo r2600
Gen10 Chassis
0 to 6 drives 25°C (77°F)
Apollo r2800
Gen10 Chassis
with SAS Expander
0 to 24 drives 25°C (77°F)
Apollo r2800
Gen10 Chassis
with 16 NVMe
0 to 4 drives 25°C (77°F)
Converged
network adapter
Apollo r2200
Gen10 Chassis
3 drives
Using an optical cable: not
supported.
Using a copper cable: 30°C
(86°F)
Apollo r2200
Gen10 Chassis
0 to 2 drives
2
Using an optical cable: 28°C
(82.4°F)
Using a copper cable: 35°C
(95°F)
Table Continued
92 Specifications