EasyManua.ls Logo

HPE ProLiant XL170r Gen10

HPE ProLiant XL170r Gen10
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description Chassis Number of LFF/SFF/NVMe
drives that correspond to
the server
Maximum inlet ambient
temperature
HPE Smart Array
P408i-p Controller
1
Apollo r2800
Gen10 Chassis
with 16 NVMe
0 to 4 drives This configuration is not
supported
HPE Smart Array
P408e-p
Controller
1
Apollo r2200
Gen10 Chassis
3 drives 22°C (71.6°F)
Apollo r2200
Gen10 Chassis
0 to 2 drives
2
30°C (86°F)
Apollo r2600
Gen10 Chassis
0 to 6 drives 30°C (86°F)
Apollo r2800
Gen10 Chassis
with SAS Expander
0 to 24 drives 30°C (86°F)
Apollo r2800
Gen10 Chassis
with 16 NVMe
0 to 4 drives 30°C (86°F)
HPE Smart Array
E208e-p
Controller
3
Apollo r2200
Gen10 Chassis
3 drives 30°C (86°F)
Apollo r2200
Gen10 Chassis
0 to 2 drives
2
35°C (95°F)
Fibre channel host
bus adapter
Apollo r2200
Gen10 Chassis
3 drives This configuration is not
supported.
Apollo r2200
Gen10 Chassis
0 to 2 drives
2
28°C (82.4°F)
Apollo r2600
Gen10 Chassis
0 to 6 drives 25°C (77°F)
Apollo r2800
Gen10 Chassis
with SAS Expander
0 to 24 drives 25°C (77°F)
Apollo r2800
Gen10 Chassis
with 16 NVMe
0 to 4 drives 25°C (77°F)
Converged
network adapter
Apollo r2200
Gen10 Chassis
3 drives
Using an optical cable: not
supported.
Using a copper cable: 30°C
(86°F)
Apollo r2200
Gen10 Chassis
0 to 2 drives
2
Using an optical cable: 28°C
(82.4°F)
Using a copper cable: 35°C
(95°F)
Table Continued
92 Specifications

Table of Contents

Other manuals for HPE ProLiant XL170r Gen10

Related product manuals