EasyManua.ls Logo

HPE ProLiant XL270d Gen9 - Page 105

HPE ProLiant XL270d Gen9
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool
before touching them.
CAUTION:
Electrostatic discharge can damage electronic components. Be sure you are properly grounded before
beginning this procedure.
To install the component:
Procedure
1. Back up all server data.
2. Power down the server .
3. Disconnect all peripheral cables from the server front panel.
4. Remove the server from the chassis.
5. Place the server on a flat, level work surface.
6. Remove the access panel.
7. Remove the air baffle.
8. Disconnect all cables from the drive backplane.
9. Remove the drive cage assembly.
10. If installed in slot 10, remove the expansion board.
a. Disconnect any internal cables that are connected to the riser module.
b. Remove the expansion board.
11. Insert a flat screwdriver into the knockout.
12. Twist and pull to remove the knockout.
Hardware options installation 105

Table of Contents

Related product manuals