Storage enclosure drawer, I/O module, and port numbering
D1D2
IOM A
IOM B
IOM A
IOM B
P2
P1
P2
P1
P2
P1
P2
P1
Cabling the first upgrade enclosure (JBOD 2)
The first upgrade enclosure is located directly above the server node.
Procedure
1. Apply the "JBOD2" label to the rear of the enclosure.
2. Apply the cable labels to the new SAS cables. The new 2 m SAS cable also requires the "F=2" label.
SAS cable Label color New label
New 0.5 m cable Red J2:D2:IA:P1 - J2:D1:IA:P2
New 0.5 m cable Green J2:D2:IB:P1 - J2:D1:IB:P2
New 1 m cable Red N:S6:P1 - J2:D1:IA:P1
New 2 m cable Green N:S6:P2 - JF:D2:IB:P2
White F=2
3. Cable the first upgrade enclosure (JBOD 2) as shown.
Installing capacity upgrade kits 115