3. In the System section, select the Maintenance mode panel.
4. On the Maintenance mode screen, set the Maintenance mode switch to the On position ( ),
and then click OK.
Installing the StoreOnce 3620 Capacity Upgrade Kit
The system comes with six 4 TB disks already installed in the left six disk bays numbered 1, 2, 5, 6, 9,
and 10; the remaining disk bays are filled with blanking plates.
The capacity upgrade kit contains six 4 TB disks that you will install in the right six disk bays numbered 3,
4, 7, 8, 11, and 12.
NOTE: All six disks in the capacity upgrade kit must be installed before you can expand storage.
1
5
2
6
9 10
3 4
7 8
11 12
Figure 18: Disk bays populated before expansion
Procedure
1. Remove the front bezel from the StoreOnce System.
Remove the locking device to unlock the security bezel. Pull the bezel out and away from the front of
the appliance.
Figure 19: Removing the locking device
72 Installing capacity upgrade kits