7. Install the base storage enclosure into the rack.
CAUTION: Use extreme caution when installing and pulling units from the rack. Unattached
units can slip and fall, damaging the StoreOnce System or causing personal injury. Hewlett
Packard Enterprise is not responsible for any damage or injury caused by mishandling the
StoreOnce system.
Always use at least two people to lift and locate an enclosure into the rack.
a. Verify that the storage enclosure has the correct JBOD number.
The storage enclosure has a pull-out tab in the upper left-hand corner of the rear panel. The tab
shows the JBOD number. In a system with multiple enclosures, having the correct JBOD numbers
on each pull-out tab will ease any necessary troubleshooting procedures.
If the enclosure was part of the initial order, the JBOD number is pre-installed on the pull-out
tab.
If the enclosure was not part of the initial order, apply the JBOD number from the sheet of
stickers to the pull-out tab.
b. Holding the handles, lift the storage enclosure onto the rails and push it into position.
The base enclosure has a JBOD label on rear of the enclosure. When installing the enclosures in
the rack, check the label to verify that you are installing the base enclosure (JBOD 1).
c. Tighten the thumbscrews to secure the enclosure to the rack.
62 HPE StoreOnce 5250 and 5650 Systems