Appendix A Parameter Shenzhen Hpmont Technology Co., Ltd.
92 HD3L Series Controller User Manual
Ref. Code
Function
Setting Range Default
Unit
Attribute Setting
F12.03 DI3 function
11 - 14: Weighing signal input 1
- 4 (WD1 - WD4)
15: Motor overheat input (OH)
16: Fault reset input (RST)
17: Up forced speed input (UPF)
18: Down forced speed input
(DNF)
19: Governor feedback inout
(OSG)
20 - 33: Unused
34: External fault (EXT)
Hundred digit = 0, normally open
input selected; = 1, normally
closed input selected
3 1
×
F12.04 DI4 function 4 1
×
F12.05 DI5 function 5 1
×
F12.06 DI6 function 6 1
×
F12.07 DI7 function 0 1
×
F12.08 DI8 function 0 1
×
F12.09 DI9 function 0 1
×
F12.10 - F12.12 Unused 0 1
×
F12.13
Filter time of multi-speed
terminal
0.000 - 2.000s 0.010s 0.001s
×
F12.14 Unused
F12.15 DO1 function
0: Unused
1: Controller is ready
2: Controller is running
3: Controller is at zero-speed
running
4: Zero-speed running
5: Contactor output control
6: Brake output control
7, 8: FDT1, FDT2
9: Speed within FAR signal
10: Up signal output
11: Down signal output
12: Under-voltage
13: Unused
14: Controller fault
15: Elevator stop signal
16 - 19: Unused
2 1
×
F12.16 DO2 function 3 1
×
F12.17 RLY1 function 14 1
×
F12.18 RLY2 function 0 1
×
F12.19 RLY3 function 0 1
×
F12.20 RLY4 function 0 1
×
F12.21 Output terminal logic setting
Bit0,Bit1: DO1,DO2 output
terminal positive / negative
logic setting
Bit2 - Bit5: RLY1 - RLY4 relay
output positive / negative logic
setting
0: Positive logic
1: Negative logic
00 1
F12.22 - F12.24 Unused
F13: Analogue I/O Terminal Parameters, on pages 61 - 63
F13.00 AI1 function 0: Unused 0 1
×