Shenzhen Hpmont Technology Co., Ltd. Appendix A Parameter
HD3L Series Controller User Manual 93
Ref. Code
Function
Setting Range Default
Unit
Attribute Setting
F13.01 AI2 function
1: Speed setting
2: Weighing signal
3: Motor overheat signal input
(only AI4 enabled)
0 1
×
F13.02 AI3 function 0 1
×
F13.03 AI4 function 0 1
×
F13.04 AI1 bias -100.0 - 100.0% 0.0% 0.1%
F13.05 AI1 gain -10.00 - 10.00 1.00 0.01
F13.06 AI1 filter time 0.01 - 10.00s 0.05s 0.01s
F13.07 AI2 bias -100.0 - 100.0% 0.0% 0.1%
F13.08 AI2 gain -10.00 - 10.00 1.00 0.01
F13.09 AI2 filter time 0.01 - 10.00s 0.05s 0.01s
F13.10 AI3 bias -100.0 - 100.0% 0.0% 0.1%
F13.11 AI3 gain -10.00 - 10.00 1.00 0.01
F13.12 AI3 filter time 0.01 - 10.00s 0.05s 0.01s
F13.13 AI4 bias -100.0 - 100.0% 0.0% 0.1%
F13.14 AI4 gain -10.00 - 10.00 1.00 0.01
F13.15 AI4 filter time 0.01 - 10.00s 0.05s 0.01s
F13.16 AO1 function
0: Unused
1: Running speed (0 - max
output speed)
2: Setting speed (0 - max output
speed)
3: Output current (0 - twice
rated current of HD3L)
4: Output voltage (0 - 1.2 times
rated voltage of HD3L)
5: DC bus voltage (0 - 2.2 times
rated voltage of HD3L)
6: AI1 input (0 - 10V)
7 - 9: AI2 - AI4 input (-10 - +10V/
0 - 20mA)
0 1
F13.17 AO2 function 0 1
F13.18 AO1 bias -100.0 - 100.0% 0.0% 0.1%
F13.19 AO1 gain 0.0 - 200.0% 100.0% 0.1%
F13.20 AO2 bias -100.0 - 100.0% 0.0% 0.1%
F13.21 AO2 gain 0.0 - 200.0% 100.0% 0.1%
F14: SCI Communication Parameters, on page 63
F14.00 Data format
0: 1-8-2 format, no parity, RTU
1: 1-8-1 format, even parity, RTU
2: 1-8-1 format, odd parity, RTU
3: 1-7-2 format, no parity, ASCII
4: 1-7-1 format, even parity,
ASCII
5: 1-7-1 format, odd parity, ASCII
0 1
×
F14.01 Baud rate
0: 1200bps
1: 2400bps
2: 4800bps
3 1
×
A