Shenzhen Hpmont Technology Co., Ltd. Appendix A Parameter
HD3L Series Controller User Manual 95
Ref. Code
Function
Setting Range Default
Unit
Attribute Setting
F15.12 Set parameter 5 of stop status
26: Input terminal status
27: Output terminal status
28: MODBUS state
29: Total time at power on (hour)
30: Total running time (hour)
31,32: Unused
27 1
F15.13 Set parameter 6 of stop status 0 1
F16: Function-boost Parameters, on pages 64 - 66
F16.00
Zero-speed running signal
delay time
0.00 - 10.00s 0.30s 0.01s
×
F16.01 Zero-speed signal delay time 0.00 - 10.00s 0.30s 0.01s
×
F16.02 Current keep time after stop 0 - 9999ms 0ms 1ms
×
F16.03 Fan control
0: Auto stop
1: Immediately stop
2: Run when power on
0 1
F16.04 Fan control delay time 0.0 - 600.0s 30.0s 0.1s
F16.05 Brake unit action voltage
220V: 380 - 450V
380V: 630 - 750V
Depend
on HD3L
1V
×
F16.06
Detection time of contactor
fault
0.1 - 10.0s 2.0s 0.1s
×
F16.07 Multi-speed inspection 0 - 7 0 1
×
F16.08 Zero-speed threshold 0.001 - 0.010m/s 0.003m/s 0.001m/s
F16.09
Selection at motor overheat
fault
0: Alarm fault after motor stops
1: Alarm fault at once
0 1
F16.10 F16.11 Unused
F16.12
Delay time of run output
signal
0.00 - 1.00s 0.00s 0.01s
×
F16.13
UPS running direction
auto-determine enable
0: Not enable
1: Enable
0 1
×
F16.14 Running min. current limit 0 - 100% (F07.11) 20% 1%
×
F16.15 Running min. detection time 0.0 - 5.0s 0.0s 0.1s
×
F16.16 Governor fault detection time 0.0 - 2.0s 1.0s 0.1s
×
F16.17 DC braking current at stop 0 – 150% 100% 1%
×
F16.18
Starting frequency of DC
braking current at stop
0.20 - 10.00Hz 0.50Hz 0.01Hz
×
F16.19 Brake release frequency 0.00 - 10.00Hz 0.00Hz 0.01Hz
×
F16.20 - F16.24 Unused
F17: Fault Protect Parameters, on pages 66 - 68
F17.00
Input voltage at motor
overheat
0.00 -10.00V 0.00V 0.01V
×
F17.01 Thermistor type
0: Not detect the motor
overheat
1: Positive charateristic
2: Negative charateristic
0 1
×
F17.02
Threshold resistance at motor
0.0 - 10.0kΩ 5.0kΩ 1.0kΩ
×