Appendix A Parameter Shenzhen Hpmont Technology Co., Ltd.
96 HD3L Series Controller User Manual
Ref. Code
Function
Setting Range Default
Unit
Attribute Setting
overheat
F17.03
The detection base of lack of
input
0 - 100% (HD3L rated voltage) 30% 1%
×
F17.04
The detection time of lack of
input
0.0 - 5.0s 1.0s 1.0s
×
F17.05
The detection base of lack of
output
0 - 100% (HD3L rated current) 20% 1%
×
F17.06
The detection time of lack of
output
0.0 - 20.0s 3.0s 1.0s
×
F17.07 Motor overload protect factor 20.0 - 110.0% 100.0% 1.0%
×
F17.08 Fault auto reset times
0 - 100
0: No auto-reset function
0 1
×
F17.09 Fault auto reset interval 2.0 - 20.0s/times 5.0s/times 0.1s/times
×
F17.10 Faulty relay action
Units: In auto reset process
0: Faulty relay doesn’t act
1: Faulty relay acts
Tens: In undervoltage process
0: Faulty relay doesn’t act
1: Faulty relay acts
00 1
F17.11 NO.5 fault type
-Lu-: DC bus undervoltage
E0001: Acc overcurrent
E0002: Dec overcurrent
E0003: Constant speed
overcurrent
E0004: Acc over voltage
E0005: Dec over voltage
E0006: Constant speed over
voltage
E0008: Power module fault
E0009: Heatsink overheated
E0010: Braking unit fault
E0011: CPU fault
E0012: Parameter auto-tuning
fault
E0013: Soft start contactor failed
E0014: Current detection fault
E0015: Input voltage phase loss
E0016: Output voltage phase
loss
E0017: Controller overload
E0018: Excessive speed
deviation
E0019: Motor overload
E0020: Motor overheat
E0021: Read / Write fault of
control board EEPROM
0 1 *