Shenzhen Hpmont Technology Co., Ltd. Appendix A Parameter
HD3L Series Controller User Manual 97
Ref. Code
Function
Setting Range Default
Unit
Attribute Setting
F17.11 NO.5 fault type
E0022: Read / Write fault of
keypad EEPROM
(display on the keypad only,
HD3L does not protect it)
E0023: Faulty setting of
parameters
E0024: Fault of external
equipment
E0025: Too small running
current
E0028: SCI ommunication
timeout
E0029: SCI communication error
E0032: Motor over speed
E0036: Contator fault
E0037: Governor fault
E0008, E0010, E0013, E0014,
E0021, E0022, E0024, E0036 can’t
auto reset
0 1 *
F17.12 Setting freqency at NO.5 fault 0.00 - 100.00Hz 0.00Hz 0.01Hz *
F17.13 Output freqency at NO.5 fault 0.00 - 100.00Hz 0.00Hz 0.01Hz *
F17.14 DC bus vlotage at NO.5 fault 0 - 999V 0V 1V *
F17.15 Output voltage at NO.5 fault 0 - 999V 0V 1V *
F17.16 Output current at NO.5 fault 0.0 - 999.9A 0.0A 0.1A *
F17.17
Input terminal status at NO.5
fault
0 - 0x1FF 0 1 *
F17.18
Output terminal status at
NO.5 fault
0 - 0x3F 0 1 *
F17.19 NO.5 fault interval 0.0 - 6553.5 hours 0.0h 0.1h *
F17.20 NO.4 fault type 0 - 36 0 1 *
F17.21 NO.4 fault interval 0.0 - 6553.5 hours 0.0h 0.1h *
F17.22 NO.3 fault type 0 - 36 0 1 *
F17.23 NO.3 fault interval 0.0 - 6553.5 hours 0.0h 0.1h *
F17.24 NO.2 fault type 0 - 36 0 1 *
F17.25 NO.2 fault interval 0.0 - 6553.5 hours 0.0h 0.1h *
F17.26 NO.1 fault type 0 - 36 0 1 *
F17.27 NO.1 fault interval 0.0 - 6553.5 hours 0.0h 0.1h *
F18: PWM Parameters, on page 68
F18.00 Carrier frequency 1 - 16kHz
Depend
on HD3L
1kHz
×
F18.01
Carrier freqency auto adjust
selection
0: Unused
1: Enable
0 1
×
F18.02 PWM overmodulation enable
0: Unused
1: Enable
1 1
×
F18.03 PWM overmodulation mode 0: Two / Three phase swtich 0 1
×