Installation
Mode
Requirements Mounting Brackets Installation
Diagram
Installing the
pRRU on a
ceiling using a
V clamp
through an
attachment
plate
For details, see
5.4.5 pRRU
Installed on a
Plate.
l The ceiling, such
as a concrete
ceiling, can bear a
load at least four
times the weight
of the pRRU.
l The thickness of
the ceiling is less
than the bolt
length (80 mm).
1. Plate
2. V clamp
3. Bolt (M6X80)
Installing the
pRRU on a
pole
For details, see
5.4.4 pRRU
Installed on a
Pole.
A pole under the
ceiling can bear a
load at least four
times the weight of
the pRRU.
For details, see Table
5-4.
For details, see Table
5-4.
Installing the
pRRU on a
keel
For details, see
5.4.6 pRRU
Installed on a
Keel.
A keel under the
ceiling can bear a
load at least four
times the weight of
the pRRU.
For details, see Table
5-5.
For details, see Table
5-5.
Installing the pRRU on a pole
When a pRRU is installed on a pole, installation modes vary with the diameter of the pole, as
shown in Table 5-4.