Parameter Name Description
High feed-in power duration threshold for
triggering inverter shutdown (s)
The default value is 20. This
parameter species the duration
threshold of high feed-in power for
triggering inverter shutdown.
When High feed-in power
duration threshold for triggering
inverter shutdown is set to 5,
Shutdown at high feed-in power
takes precedence.
When High feed-in power
duration threshold for triggering
inverter shutdown is set to 20,
Grid connection with limited
power takes precedence (when
Active power control is set to
Grid connection with limited
power).
Note a: This parameter is supported only for the AS4777 grid code.
----End
7.2.1.2 Apparent Power Control on the Inverter Output Side
On the home screen, tap Settings > Power adjustment to set inverter
parameters.
Figure 7-12 Apparent power control
SUN2000-(3KTL-10KTL)-M1 Series
User Manual 7 Man-Machine Interaction
Issue 17 (2024-01-12) Copyright © Huawei Technologies Co., Ltd. 93

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000-8KTL-M1 and is the answer not in the manual?

Huawei SUN2000-8KTL-M1 Specifications

General IconGeneral
Max. Efficiency98.6%
Max. Input Voltage1100 V
Nominal Input Voltage600 V
Number of MPP Trackers2
Max. Output Power8000 W
Nominal Output Frequency50 Hz / 60 Hz
Weight17 kg
Max. apparent AC power8800 VA
Rated AC power8000 W
Operating Temperature Range-25°C to +60°C
CoolingNatural Convection
Protection DegreeIP65
Warranty10 years
Nominal Output Voltage230 V / 400 V